SUNTEST CPS/CPS+
This economical xenon test instrument is the smallest of the SUNTEST Family with 560 cm<sup>2</sup> of exposure area. It is equipped with a flat specimen tray and is perfect for companies on a limited budget or for companies that occasionally have the need to test.
The CPS+ uses the Atlas microprocessor control package to deliver a controlled and reproducible test. The manual CPS model is an economical alternative offering basic manual control and the lowest priced xenon exposure system.
- Two models: manual CPS and fully automated CPS+
- CPS+ model offers full micro-processor control and simple test programming
- Light source: 1500 watt air cooled xenon arc lamp
- Total exposure area: 560 cm2 (86 in2)
- Temperature range: BST 35 ºC to 100 ºC
- Controlled irradiance
- Measurement and display of chamber temperature
- Unique chamber design for better distribution of ultraviolet radiation
- Low cost operation
- Filter combinations
- Water-cooled specimen table for exposure of thermo-sensitive samples
- Immersion system
Subframe for testing the weather resistance of materials, e. g. paints, plastics or building materials (only for SUNTEST CPS+)
- Sample fitting (2 pcs)
- Special adapter to fit the XenoCal sensor into the SUNTEST CPS/CPS+ (sample table)
- Set of cover masks with 39 mm windows (4 pcs)
- 230 V± 10%, 50 Hz
- Set of insulation pads
- Condensate pump 50 / 60 Hz
- Low Ambient Temp. Kit SUNTEST 50 Hz
- Low Ambient Temp. Kit SUNTEST 60 Hz
- Spare parts set
- Xenon Burner NXE 1500 B
- Special UV glass
- "Solar Standard"
- Solar ID65 filter
- Store Light® filter
- Uncoated quartz filter
- XenoCal® WB 300-800
- White standard thermometer (WST)
- SunTray
Subframe for SUNTEST CPS / CPS+. Sample exchanger that allows save sample removal while the instrument is running. Designed for COLIPA (2007A method) testing with short eposure durations.
- Daylight filter
Reference Test Specifications include:
Reference Test Specifications include:
- Cosmetics
- Pharmaceuticals
- Plastics
- Textiles
- Sealants
- Dental Materials
- Printing Inks
-
ASTM D3424
Standard Test Methods for Evaluating the Relative Lightfastness and Weatherability of Printed Matter
-
ASTM D5071
Standard Practice for Exposure of Photodegradable Plastics in a Xenon Arc Apparatus
-
ASTM D6695
Standard Practice for Xenon-Arc Exposures of Paint and Related Coatings
-
ASTM G151
Standard Practice for Exposing Nonmetallic Materials in Accelerated Test Devices that Use Laboratory Light Sources
-
ASTM G155
Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials
-
ICH Guideline Q1B
Guideline for the photostability testing of new drug substances and products
-
ISO 11431
Building construction - Jointing products - Determination of adhesion/cohesion properties of saelants after exposure to heat, water and artificial light through glass
-
ISO 11979-5
Ophtalmic implants - Intraocular lenses - Part 5: Biocompatibility
-
ISO 7491
Dental materials - Determination of colour stability
-
ISO 4049
Dentistry. Polymer-base filling, restorative and luting materials
-
ISO 4892-1
Plastics - Methods of exposure to laboratory light sources - Part 1: General guidance
-
ISO 4892-2
Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc sources
-
ISO 10977
Photography - Processed photographic colour films and paper prints - Methods for measuring image stability
-
COLIPA 2007A
METHOD FOR THE IN VITRO DETERMINATION OF UVA PROTECTION PROVIDED BY SUNSCREEN PRODUCTS
- Lamps
- Set of Air Filters (Chamber)
- Ignition Diode
- Window Glass Filter
TOP