atlas-ametek logoSkip to Main Content
No options found

Top 10 Fluorescent UV Testing Standards You Should Know

This Atlas Weathering Blog Post presents the most referenced international fluorescent UV testing standards for coatings, plastics, and other materials and products. Learn about key guidelines, applications, and further resources.

Fluorescent UV devices exposing material samples to ultraviolet light

Recent discussions have highlighted key standards for xenon-arc and outdoor weathering testing. Building on this approach, we now identify the ten most widely used and referenced fluorescent UV (Fl/UV) testing standards. This overview focuses exclusively on international consensus-based documents, such as ISO, EN, and ASTM, while excluding industry-specific and company test methods.

General Guidance

Both ISO 4892-1 – Plastics - Methods of exposure to laboratory light sources - General guidance and ASTM G151 - Standard Practice for Exposing Nonmetallic Materials in Accelerated Test Devices that Use Laboratory Light Sources provide general guidance for all laboratory light sources. These standards are already discussed in the blog post about top 10 xenon standards. The following is on fluorescent UV exposures exclusively.

  1. ASTM G154 - Standard Practice for Operating Fluorescent Ultraviolet (UV) Lamp Apparatus for Exposure of Nonmetallic Materials.

This practice provides general guidance for operating fluorescent UV devices for a wide range of exposure conditions. ASTM G154 is technically equivalent to ISO 4892-3 for plastics and ISO 16474-3 for coatings. ASTM G154, along with ASTM G151 for general guidance, replace the previous instrument-specific standard ASTM G53.

Coatings

  1. ISO 16474-3 - Paints and varnishes - Methods of exposure to laboratory light sources – Part 3: Fluorescent UV lamps.

Part 3 of the ISO 16474 series on paints and varnishes specifies testing with fluorescent UV devices, similar to Part 2, which focuses on xenon exposures.

  1. ASTM D4587 - Standard Practice for Fluorescent UV-Condensation Exposures of Paint and Related Coatings.

ASTM D4587 includes a selection of test conditions for accelerated exposure testing for coatings and related products in fluorescent UV and condensation devices, conducted in accordance with ASTM practices G151 and G154.

  1. EN 927-6 - Paints and varnishes - Coating materials and coating systems for exterior wood – Part 6: Exposure of wood coatings to artificial weathering using fluorescent UV lamps and water.

This European standard refers to ISO 16474-3, specifically focusing on coatings on wood. An additional part of series EN 927 on xenon exposure is in discussion but work has not yet started.

Plastics

  1. ISO 4892-3 – Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps.

Part 3 of ISO 4892 series on laboratory weathering of plastics specifies fluorescent UV testing devices in a similar way as Part 2 does for xenon exposures. In addition to the widely used condensation type devices, climatic chamber type instruments are also described.

  1. ASTM D4329 - Standard Practice for Fluorescent Ultraviolet (UV) Exposure of Plastics.

ASTM D4329 and ISO 4892‑3 address the same subject matter but differ in technical content and instrument settings.

Bituminous Materials

  1. ASTM D4799 - Standard Test Method for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Fluorescent UV and Condensation Method).
  2. EN 1297 - Flexible sheets for waterproofing - Bitumen, plastic, and rubber sheets for roofing - Method of artificial ageing by long term exposure to the combination of UV radiation, elevated temperature and water.

Both standards specify fluorescent UV and condensation exposure of materials used for roofing and waterproofing but in a slightly different way. ASTM D4799 refers to the basic ASTM G151 and G154 practices. EN 1297, however, refers to the basic standards ISO 4892‑1 and ISO 4892‑3.

Geotextiles

  1. ASTM D7238 - Standard Test Method for Effect of Exposure of Unreinforced Polyolefin Geomembrane Using Fluorescent UV Condensation Apparatus

It should be mentioned that there is a European standard for the same application. EN 12224 - Geotextiles and geotextile-related products - Determination of the resistance to weathering specifies UV lamps for testing according to ISO 4892‑3.

Coil Coated Metals

  1. EN 13523-10 - Coil coated metals - Test methods – Part 10: Resistance to fluorescent UV light and water condensation

This European standard relates to basic guidelines in ISO 16474-3. The EN 13523 series consists of 29 parts, with part 19 specifying outdoor weathering exposure and part 21 the evaluation of samples from outdoor tests.

Diagram of a typical Fluorescent UV device
Diagram of a typical Fluorescent UV device
The Atlas UVTest fluorescent UV testing device
Atlas UVTest fluorescent UV instrument
Andreas Riedl
About Andreas Riedl
Director of Marketing
Andreas Riedl holds degrees in mathematics, biology, and physical chemistry from Georg August University in Goettingen, Germany. He has 34 years experience in material and product performance testing, test method development and technical standardization, and 27 years in weathering. Functional experience includes product management, standards committee representation, new business development, technical consulting, and marketing. His publications and articles include test method development, weathering technology, methods, and applications, optical imaging, and environmental durability of photovoltaics. Andreas Riedl chairs the SKZ Symposium on Weathering of Plastics and has been session chairman in national and international conferences.

Brochures