Sensors for Temperature Control in Weathering Instruments

This Atlas Weathering Blog Post explains why xenon‑arc testing requires both black panel and chamber air sensors to replicate realistic specimen surface temperatures, ensuring accurate and repeatable weathering results that reflect true material degradation behavior.

close-up view of SUNTEST XXL test chamber with BST and CHT temperature sensors indicated

Xenon-arc weathering instruments use black surface temperature sensor in addition to a air temperature sensor to provide a more accurate representation of the test conditions experienced by the materials being tested. For precise testing, a xenon weathering instrument must be equipped with both sensors.

Black Standard (BST) / Black Panel (BPT)

BPT means “Black Panel Temperature”, BST means “Black Standard Temperature”. 

  • BPT and BST sensors use metal plates with an extra-durable black coating to absorb radiation effectively, mimicking the highest realistic surface temperature of a test specimen that absorbs heat from radiation.
  • Black standard temperature sensors are standardized in ISO 4892-1 and are referred to as “insulated black panel sensors” in ASTM G151. Black panel temperature sensors are sometimes also referred to as “uninsulated black panel sensors”.
  • BPT and BST can differ significantly (>20 K) from the chamber air temperature (CAT) due to differences in heat exchange with the environment.
  • The rate of degradation is highly dependent on the specimen temperature. Since photooxidation always starts at the surface of the specimen, its surface temperature is the most relevant factor.

Chamber Air Temperature (CAT) 

  • The chamber air temperature sensor must be shielded from radiation.
  • CAT monitoring assists in the maintenance of the overall thermal environment within the test chamber. This ensures more consistent and reproducible test conditions.
  • CAT alone doesn’t account for the actual surface temperature of a colored test specimen, so it is insufficient as the sole metric in a weathering test.

Note: CAT was formerly called CHT 

Why Combining Both Sensors

  • Realistic simulation: Outdoor weathering conditions involve a combination of radiant heat and ambient air temperature. Using both sensors helps replicating this environment more accurately.
  • Material-specific effects: Different materials absorb and dissipate heat differently, and their degradation majorly depends on their surface temperature.
  • Support of repeatability: Many industry standards (e.g., ASTM, ISO) require control of both black panel and chamber air temperature to ensure test results are well repeatable and reproducible across different instruments.

In summary, the use of both temperature sensors for black panel and chamber air ensures a more comprehensive evaluation of environmental stress factors on materials. Thus, leading to more reliable weathering test results.

Dr. Oliver D. Rahäuser
About Dr. Oliver D. Rahäuser
Senior Product Manager

Dr. Oliver Rahaeuser user studied Chemistry in Wuerzburg, Germany. He received his Diploma in Inorganic Chemistry and Material Science, followed by his Ph.D. Oliver joined Atlas MTT in 2006 functioning as Product Manager for the SUNTEST® and Xenotest® accelerated weathering testing instrument product lines. Since 2013, he added Product Management of Atlas Custom Systems, which primarily focuses on tailored solar simulator solutions for small and large test chambers for component and product testing. Dr. Oliver Rahaeuser is a member of the German Colour Fastness Committee, and the DKE committees on PV and environmental testing of electronics. Furthermore, he consults Atlas clients on accelerated aging testing and test method development.